knobconfig
assigns knobs to devices
according to the input file. Knob assignments are active
only during program execution.
knobconfig SR_tunes.coknwhere file
SR_tunes.cokn
contains weights for the various
quadrupole magnets necessary for independent tune adjustments.
Part of the first data set of the file SR_tunes.cokn
is shown below:
SDDS1 &description text="Knob Assignment Specification" contents="knob assignment specification" &end ¶meter name=ControlName, type=string &end ¶meter name=KnobDescription, type=string &end ¶meter name=ControlType, type=string &end ¶meter name=ControlUnits, type=string &end ¶meter name=Gain type=double &end &column name=ControlName type=string &end &column name=Weight type=double &end &data mode=ascii, &end S:NUx:fine ! ControlName Triplet knob for x tune (0.0005/click) ! KnobDescription dev ! ControlType ? ! ControlUnits 0.5 ! Gain 240 ! number of rows S1A:Q1 1.488923268326000e-03 S1A:Q2 5.958927747443000e-03 S1A:Q3 4.242561180246000e-03 S1B:Q3 4.242561180246000e-03 S1B:Q2 5.958927747443000e-03 S1B:Q1 1.488923268326000e-03 S2A:Q1 1.488923268326000e-03 S2A:Q2 5.958927747443000e-03 ...
usage: knobconfig spec-file purpose: Configures knobs. Assigns knobs to devices and process variables according to spec-file. Assignments are active only during program execution. In general, it is best not to run this utility in background. Sample spec-file. Note that ControlMessage parm is optional: SDDS1 &description text="Knob Assignment Specification" contents="knob assignment specification" &end ¶meter name=ControlName type=string &end ¶meter name=ControlType type=string &end ¶meter name=ControlMsg type=string &end ¶meter name=ControlUnits type=string &end ¶meter name=Gain type=double &end &column name=ControlName type=string &end &column name=Weight type=double &end &data mode=ascii no_row_counts=1 &end COMPDEVICENAME dev set tune 0.01 P:Q1 1.0000 P:Q2 1.1134 PTB:Q3 dev set Amps 0.1 PTB:Q4:CurrentAO pv - Amps 0.1
Each data set in the input file defines the weights of the devices controlled by one knob. The required parameters are:
dev
".
KnobDesciption
and Units
may be implemented in future versions
of knobconfig
. For now, they may be defined as a data preparation aid.
The required columns are:
Gain
, these are the values by which each device
setpoints will be changed by one tick of the knob.