Listing of Statistics for Run7-1997 Total Amount of User Time in this interval 741.86 Hours User periods in this interval ----------------------------- 10/20/1997 08:03 To 10/27/1997 08:05 169.04 Hours 10/28/1997 08:00 To 11/03/1997 08:11 144.18 Hours 11/04/1997 08:00 To 11/10/1997 08:04 144.06 Hours 11/11/1997 11:34 To 11/17/1997 08:04 140.50 Hours 11/18/1997 08:01 To 11/24/1997 08:05 144.07 Hours Delivered Beam 698.24 Hours Percentage of Scheduled Time 94.12 % Downtime During Period 43.62 Hours Percentage of scheduled time SR current > 10 ma 97.54 % Average Delivered Current During This Period 75.82 ma Total integrated Current During This Period 52.94 A-hr Median Fill Duration in Period 19.61 Hours Mean Fill Duration in Period 38.79 Hours Mean Fill Duration from Poisson Fit 44.35 Hours Faults per Day of Delivered Beam 0.58 Length Downtime is associated with the end of a fill. Valid fills Beginning in this Time Interval| Reason for | of The first fill of a period will have any Fill# Start End Duration | Fill Termination | Downtime downtime before the fill on the line above. ------------------------------------------------------------------------------------------------------------------------------------ | | 0.00 # 1 10/20 08:03 To 10/20 15:28 7.41 | rad monitor tripped rf | 2.22 fix of rad monitor # 2 10/20 17:41 To 10/21 06:15 12.58 | Int Dump: Low Current | 0.36 ..... # 3 10/21 06:37 To 10/22 02:24 19.79 | Int Dump: Low Current | 0.43 ..... # 4 10/22 02:50 To 10/23 05:59 27.15 | Int Dump: Low Current | 0.43 ..... # 5 10/23 06:25 To 10/23 10:55 4.51 | Rad monitor tripped rf | 2.79 rf problems, raw PS problems # 6 10/23 13:43 To 10/23 16:11 2.47 | rf3 SL2 Cav4 ION GA | 0.69 recovery # 7 10/23 16:52 To 10/24 06:00 13.13 | Int Dump: Low Current | 0.48 ..... # 8 10/24 06:28 To 10/25 06:00 23.54 | Int Dump: Low Current | 0.43 ..... # 9 10/25 06:26 To 10/26 05:59 24.55 | Int Dump: Low Current | 0.70 ..... # 10 10/26 06:41 To 10/27 08:05 25.40 | Int Dump: End of Period | 0.00 ..... ------------------------------------------------------------------------------------------------------------------------------------ | | 0.30 Prepare for shielding verification # 11 10/28 08:18 To 10/28 08:49 0.52 | Int Dump: End of Period | 1.09 Trouble injecting, beam dropped out of SR # 12 10/28 09:55 To 10/28 16:44 6.82 | Int Dump: Low Current | 2.73 problems switching pumps, inj prob, beam torroid # 13 10/28 19:27 To 10/29 06:00 10.55 | Int Dump: Low Current | 0.43 ..... # 14 10/29 06:26 To 10/29 14:14 7.79 | rf2 power splitter | 1.92 recovery # 15 10/29 16:09 To 10/30 06:00 13.85 | Int Dump: Low Current | 0.32 ..... # 16 10/30 06:19 To 10/31 06:01 23.69 | Int Dump: Low Current | 0.37 ..... # 17 10/31 06:23 To 10/31 11:24 5.01 | PS trip, door interlock | 1.29 recovery # 18 10/31 12:41 To 11/01 01:32 12.85 | PS induced beam motion | 0.63 ..... # 19 11/01 02:10 To 11/01 06:24 4.22 | Int Dump: Low Current | 0.42 ..... # 20 11/01 06:49 To 11/02 06:51 24.03 | Int Dump: Low Current | 0.40 ..... # 21 11/02 07:14 To 11/02 07:49 0.57 | VM-04-VV0? closed | 0.54 ..... # 22 11/02 08:21 To 11/03 08:01 23.67 | Int Dump: Low Current | 0.18 ..... ------------------------------------------------------------------------------------------------------------------------------------ | | 0.40 SRF-2 power monitor trip on SL3 Cavity 1 Ion Ga Flt # 23 11/04 08:24 To 11/05 06:08 21.72 | Int Dump: Low Current | 0.48 ..... # 24 11/05 06:36 To 11/06 06:01 23.41 | Int Dump: Low Current | 0.50 ..... # 25 11/06 06:31 To 11/06 10:51 4.33 | H2O pres drop, sec14-17 | 1.45 recovery # 26 11/06 12:18 To 11/07 06:01 17.72 | Int Dump: Low Current | 0.56 ..... # 27 11/07 06:35 To 11/08 06:03 23.46 | Int Dump: Low Current | 0.55 ..... # 28 11/08 06:36 To 11/09 05:58 23.38 | rf2 HVPS trip | 2.34 rf system swap, S24/25:R3 tripped on AC/DC OI # 29 11/09 08:18 To 11/09 10:55 2.60 | Unknown beam motion | 0.64 Recovery # 30 11/09 11:33 To 11/09 18:09 6.61 | Unknown Beam Motion | 0.68 Recovery # 31 11/09 18:50 To 11/10 08:01 13.18 | Int Dump: End of Period | 0.05 ..... ------------------------------------------------------------------------------------------------------------------------------------ | | 0.00 # 34 11/11 11:34 To 11/11 15:31 3.95 | Int Dump: End of Period | 0.70 refill to 100ma after 25, lattice change # 35 11/11 16:13 To 11/11 16:19 0.10 | rf GPIB errors | 0.58 recovery # 36 11/11 16:54 To 11/12 06:02 13.13 | Int Dump: Low Current | 0.41 ..... # 37 11/12 06:26 To 11/13 06:20 23.89 | Int Dump: Low Current | 3.67 converter swapout, linac problems # 38 11/13 10:00 To 11/14 04:16 18.27 | Int Dump: Low Current | 1.00 injection problems, linac L3 trip # 39 11/14 05:16 To 11/15 06:59 25.73 | Int Dump: Low Current | 0.90 BTS control law problems slowed fill rate # 40 11/15 07:53 To 11/16 06:00 22.12 | Int Dump: Low Current | 2.32 2ID gap problems, rf stations trip due to rad mon # 41 11/16 08:20 To 11/17 08:01 23.68 | Int Dump: End of Period | 0.06 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.02 # 42 11/18 08:02 To 11/18 11:11 3.16 | Int Dump: End of Period | 0.58 ..... # 43 11/18 11:46 To 11/18 19:59 8.22 | rf2 circulator fault | 0.60 recovery # 44 11/18 20:35 To 11/19 06:00 9.41 | Int Dump: Low Current | 0.31 ..... # 45 11/19 06:18 To 11/19 16:30 10.20 | VM-34-VV02 closed | 1.27 SR rf problems # 46 11/19 17:47 To 11/19 22:11 4.41 | S17A:Q5 PS glitch | 0.55 ..... # 47 11/19 22:44 To 11/20 00:52 2.13 | S17A:Q5 PS glitch | 1.37 L4 rf problems # 48 11/20 02:14 To 11/20 14:11 11.95 | S17A:Q5 glitch | 1.23 replaced S17A:Q5 converter # 49 11/20 15:25 To 11/21 09:10 17.75 | Int Dump: Low Current | 0.57 lowered current in S11A:S4 to reduce beam motion # 50 11/21 09:44 To 11/22 06:01 20.27 | Int Dump: Low Current | 0.34 ..... # 51 11/22 06:21 To 11/23 06:15 23.89 | Int Dump: Low Current | 0.36 ..... # 52 11/23 06:36 To 11/24 08:04 25.47 | Int Dump: End of Period | 0.01 ..... |