Listing of Statistics for Run2-2001 Total Amount of User Time in this interval 1240.0 Hours User periods in this interval ----------------------------- 05/09/2001 08:01 To 05/15/2001 07:59 143.98 Hours, Delivered Beam: 133.85 Hours, 7 Fault(s), 19.12 MTBF, 92.97% of Sched. Time 05/15/2001 16:00 To 05/21/2001 07:59 135.98 Hours, Delivered Beam: 119.89 Hours, 4 Fault(s), 29.97 MTBF, 88.17% of Sched. Time 05/23/2001 08:00 To 05/28/2001 07:59 119.98 Hours, Delivered Beam: 117.80 Hours, 2 Fault(s), 58.90 MTBF, 98.18% of Sched. Time 05/29/2001 08:00 To 06/04/2001 08:00 143.99 Hours, Delivered Beam: 140.20 Hours, 3 Fault(s), 46.73 MTBF, 97.37% of Sched. Time 06/06/2001 08:00 To 06/12/2001 07:59 143.98 Hours, Delivered Beam: 140.95 Hours, 3 Fault(s), 46.98 MTBF, 97.89% of Sched. Time 06/12/2001 16:00 To 06/18/2001 07:59 135.98 Hours, Delivered Beam: 134.36 Hours, 3 Fault(s), 44.79 MTBF, 98.81% of Sched. Time 06/20/2001 08:00 To 06/26/2001 07:59 143.98 Hours, Delivered Beam: 132.74 Hours, 5 Fault(s), 26.55 MTBF, 92.19% of Sched. Time 06/26/2001 16:01 To 07/04/2001 07:59 183.97 Hours, Delivered Beam: 180.17 Hours, 5 Fault(s), 36.03 MTBF, 97.93% of Sched. Time 07/05/2001 08:00 To 07/08/2001 24:00 87.99 Hours, Delivered Beam: 84.22 Hours, 3 Fault(s), 28.07 MTBF, 95.72% of Sched. Time Delivered Beam 1184.18 Hours Percentage of Scheduled Time 95.51 % Downtime During Period 55.66 Hours Percentage of scheduled time SR current > 10 ma 96.40 % Average Delivered Current During This Period 85.68 ma Total integrated Current During This Period 101.46 A-hr Mean Fill Duration in Period 32.18 Hours Mean Fill Duration from Poisson Fit 35.31 Hours Mean Time Between Faults (MTBF) 33.83 Hours Faults per Day of Delivered Beam 0.71 Length Downtime is associated with the end of a fill. Valid fills Beginning in this Time Interval| Reason for | of The first fill of a period will have any Fill# Start End Duration | Fill Termination | Downtime downtime before the fill on the line above. ------------------------------------------------------------------------------------------------------------------------------------ | | 0.00 # 1 05/09 08:00 To 05/10 07:44 23.73 | To close shutters [CTL] | 0.09 ..... # 3 05/10 07:49 To 05/10 13:40 5.85 | S3B:Q2 glitch [PS] | 2.00 acis validation of top-up interlocks, rf trips # 4 05/10 15:40 To 05/10 18:28 2.79 | S3B:Q2 glitch [PS] | 0.43 slow refill due to rf coupler conditioning # 5 05/10 18:54 To 05/11 10:24 15.51 | ID22 EPS trip [ISI] | 1.71 converter swap, ioc problem, refill # 7 05/11 12:07 To 05/11 14:34 2.44 | S27BQ4 trip [PS] | 1.50 Diagnosis and repair # 8 05/11 16:03 To 05/14 19:51 75.79 | S37 Cav.Vac trip [RF] | 2.32 Cavity vacuum trip during injection, refill # 15 05/14 22:10 To 05/15 03:43 5.56 | S29 Water trip [ID-FE] | 2.08 Investigate, refill # 16 05/15 05:48 To 05/15 07:59 2.18 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.13 # 17 05/15 16:08 To 05/16 07:38 15.50 | RF4 HVPS trip [RF] | 0.40 Refill # 19 05/16 08:02 To 05/17 07:45 23.72 | unknown beam loss [UKN] | 0.57 refill # 21 05/17 08:19 To 05/17 17:07 8.79 | RF3 output arc [RF] | 13.69 Booster Ext. septum H2O leak, water damaged kicker # 22 05/18 06:48 To 05/18 15:46 8.97 | 10BM PSS trip [CTL/ISI] | 1.30 Investigation, refill # 23 05/18 17:04 To 05/21 07:59 62.91 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.02 # 34 05/23 08:01 To 05/23 20:31 12.49 | Rad mon. trip [OPS] | 1.01 refill # 35 05/23 21:31 To 05/26 09:58 60.45 | MPS trip on water [ME] | 1.15 BPLD pending, refill # 41 05/26 11:07 To 05/28 07:59 44.87 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.00 # 45 05/29 08:00 To 05/30 12:41 28.69 | 9ID ACIS trip [CTL/ISI] | 0.85 investigate, refill # 48 05/30 13:32 To 05/30 23:11 9.64 | S13B:Q4 trip [PS] | 1.43 PS swap, refill # 50 05/31 00:36 To 05/31 07:03 6.44 | MPS vac/water trip [VAC] | 1.51 investigate, refill # 51 05/31 08:33 To 06/04 07:59 95.43 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.00 # 60 06/06 08:00 To 06/08 19:34 59.57 | 10BM PSS trip [CTL/ISI] | 1.12 recovery # 65 06/08 20:42 To 06/11 03:15 54.56 | S40 Vacuum [RF] | 1.18 recovery # 70 06/11 04:26 To 06/12 05:59 25.55 | S37 Cav. Vac [RF] | 0.74 refill # 72 06/12 06:43 To 06/12 07:59 1.26 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.08 EPS fault not clear # 73 06/12 16:05 To 06/12 19:45 3.68 | Unknown beam loss [UKN] | 0.77 Investigate, refill # 74 06/12 20:32 To 06/15 18:39 70.11 | RF3 mod Anode trip [RF] | 0.39 refill # 80 06/15 19:02 To 06/16 19:59 24.94 | Int.dump,water leak [ME] | 0.38 Refill # 82 06/16 20:22 To 06/18 07:59 35.62 | Fill Ongoing | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.05 # 85 06/20 08:03 To 06/20 13:25 5.37 | 9ID PSS trip [CTL/ISI] | 1.27 Recovery, PEM tool problem # 86 06/20 14:41 To 06/22 14:46 48.09 | Kicker Setpnt error [PS] | 0.30 Refill # 87 06/22 15:05 To 06/23 23:59 32.92 | ACIS trip [CTL] | 3.80 Investigate, repair, conditioning, refill # 88 06/24 03:47 To 06/25 19:31 39.73 | S10A:Q1 fault [PS] | 3.07 Investigation, convertor swap, refill # 90 06/25 22:35 To 06/26 00:26 1.86 | ACIS trip [CTL] | 2.76 Investigation, refill # 91 06/26 03:12 To 06/26 07:59 4.78 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.02 # 93 06/26 16:01 To 06/26 19:42 3.68 | Unknown beam loss [UKN] | 0.90 investigation, refill # 94 06/26 20:36 To 06/28 11:06 38.50 | 20BM PSS trip [ISI] | 0.82 Investigate, refill # 95 06/28 11:55 To 07/02 10:13 94.30 | P0 timing error [CTL] | 0.60 refill # 96 07/02 10:49 To 07/03 11:05 24.27 | Unknown BPLD trip [UKN] | 0.36 refill # 97 07/03 11:27 To 07/04 06:52 19.42 | Unknown trip [CTL] | 1.12 Restore communication, end of period ------------------------------------------------------------------------------------------------------------------------------------ | | 0.02 S19BP1 BPLD problem # 98 07/05 08:01 To 07/05 15:45 7.74 | S32:33 grnd fault [ME] | 2.24 Investigate, refill # 99 07/05 17:59 To 07/06 14:56 20.95 | S34A:Q4 trip [PS] | 1.14 Investigation, refill #100 07/06 16:05 To 07/07 01:46 9.68 | Shutters Closed [CTL] | 0.37 Booster ACIS trip, recover #101 07/07 02:08 To 07/08 23:59 45.85 | Int Dump: End of Period | 0.00 Top-Up Mode Statistics ---------------------- Target Current = 102.0, Range +/- 1.0, Minimum Injector Downtime = 8.0 minutes Total Scheduled Topup Time 328.0 Hours Injector Availability 98.0 %