Listing of Statistics for Run1-2003 (Created Tue May 27 09:12:04 CDT 2003) Total Amount of User Time in this interval 1646.93 Hours User periods in this interval ----------------------------- 01/29/2003 08:00 To 02/03/2003 16:00 128.00 Hours, Delivered Beam: 121.59 Hours, 3 Fault(s), 40.53 MTBF, 94.99% of Sched. Time 02/04/2003 08:00 To 02/10/2003 08:00 144.00 Hours, Delivered Beam: 140.97 Hours, 3 Fault(s), 46.99 MTBF, 97.90% of Sched. Time 02/12/2003 08:00 To 02/18/2003 08:00 144.00 Hours, Delivered Beam: 139.42 Hours, 3 Fault(s), 46.47 MTBF, 96.82% of Sched. Time 02/18/2003 16:00 To 02/24/2003 08:00 136.00 Hours, Delivered Beam: 133.69 Hours, 4 Fault(s), 33.42 MTBF, 98.30% of Sched. Time 02/26/2003 08:00 To 03/03/2003 16:00 128.00 Hours, Delivered Beam: 123.55 Hours, 7 Fault(s), 17.65 MTBF, 96.52% of Sched. Time 03/04/2003 08:00 To 03/10/2003 08:00 144.00 Hours, Delivered Beam: 139.27 Hours, 3 Fault(s), 46.42 MTBF, 96.71% of Sched. Time 03/12/2003 08:00 To 03/18/2003 08:00 144.00 Hours, Delivered Beam: 141.48 Hours, 2 Fault(s), 70.74 MTBF, 98.25% of Sched. Time 03/18/2003 16:00 To 03/24/2003 08:00 136.00 Hours, Delivered Beam: 134.91 Hours, 3 Fault(s), 44.97 MTBF, 99.20% of Sched. Time 03/26/2003 08:00 To 04/01/2003 08:00 144.00 Hours, Delivered Beam: 142.15 Hours, 3 Fault(s), 47.38 MTBF, 98.71% of Sched. Time 04/01/2003 16:00 To 04/07/2003 08:00 135.00 Hours, Delivered Beam: 130.07 Hours, 4 Fault(s), 32.52 MTBF, 96.35% of Sched. Time 04/09/2003 08:00 To 04/14/2003 16:00 128.00 Hours, Delivered Beam: 126.58 Hours, 2 Fault(s), 63.29 MTBF, 98.89% of Sched. Time 04/15/2003 08:00 To 04/20/2003 24:00 136.00 Hours, Delivered Beam: 125.12 Hours, 8 Fault(s), 15.64 MTBF, 92.00% of Sched. Time Delivered Beam 1598.80 Hours Percentage of Scheduled Time (*) 97.08 % Downtime During Period 48.14 Hours Percentage of scheduled time SR current > 10 ma 98.14 % Average Delivered Current During This Period 98.37 ma Total integrated Current During This Period 157.31 A-hr Mean Fill Duration in Period 34.76 Hours Mean Fill Duration from Poisson Fit 34.13 Hours Mean Time Between Faults (MTBF) 35.53 Hours Faults per Day of Delivered Beam 0.68 Length Downtime is associated with the end of a fill. Valid fills Beginning in this Time Interval| Reason for | of The first fill of a period will have any Fill# Start End Duration | Fill Termination | Downtime downtime before the fill on the line above. (min: 1.0) | | ------------------------------------------------------------------------------------------------------------------------------------ | | 0.00 # 1 01/29 08:00 To 01/30 07:44 23.74 | Correct P0 Err. [CTL] | 0.85 Recover, refill # 3 01/30 08:36 To 01/30 13:59 5.38 | line power bump [OTHER] | 2.08 Investigation, Recovery of injector[OAG], refill # 4 01/30 16:03 To 02/02 02:28 58.40 | 18ID Rad. Mon. Trip [HP] | 3.48 Repair, RF rad monitor problems # 11 02/02 05:56 To 02/03 15:59 34.06 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.19 Lost beam when engaging RTFB system [ES] # 15 02/04 08:11 To 02/07 08:34 72.38 | rf4 Vac trip [RF] | 0.73 Pump down, refill # 16 02/07 09:18 To 02/07 16:19 7.02 | rf4 llrf trip [RF] | 1.81 Refill # 18 02/07 18:08 To 02/09 13:36 43.48 | rf4 Vac trip [RF] | 0.29 Refill # 20 02/09 13:54 To 02/10 07:59 18.09 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.00 # 23 02/12 08:00 To 02/15 11:09 75.16 | 1ID BPLD trip [DIAG] | 0.70 Lost beam again, refill # 26 02/15 11:51 To 02/15 14:26 2.58 | 1ID BPLD trip [DIAG] | 2.04 refill # 28 02/15 16:28 To 02/15 18:14 1.77 | RF4 sideband [RF] | 1.83 RF system swapping, refill # 30 02/15 20:04 To 02/18 07:59 59.92 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.00 # 31 02/18 16:00 To 02/19 02:52 10.86 | S9BQ2 failure [ES] | 1.23 Converter swapping, conditioning and refill # 32 02/19 04:06 To 02/20 05:39 25.56 | RF2 crowbar trip [RF] | 0.22 Refill # 33 02/20 05:53 To 02/22 17:20 59.46 | RF2 crowbar trip [RF] | 0.62 Lost beam again, Refill # 35 02/22 17:57 To 02/24 00:21 30.40 | S40 Cav.Vac. trip [RF] | 0.22 refill # 36 02/24 00:35 To 02/24 07:59 7.41 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.01 # 38 02/26 08:00 To 02/26 09:50 1.83 | RF3 loss due to RF2 [RF] | 1.26 Refill # 40 02/26 11:06 To 02/26 16:48 5.71 | IOCRFTime problem [CTL] | 0.88 Refill # 41 02/26 17:41 To 02/26 23:50 6.15 | IOCRFTIME problem [CTL] | 0.27 refill # 42 02/27 00:06 To 02/28 17:27 41.35 | RF3 loss due to RF2 [RF] | 0.41 Refill # 43 02/28 17:52 To 03/01 12:17 18.42 | Rad.mon.trip @inj. [OPS] | 0.35 Refill # 45 03/01 12:38 To 03/01 18:54 6.27 | 22ID BPLD trip [UKN] | 1.04 Loss beam again, refill # 48 03/01 19:56 To 03/03 09:18 37.37 | RF3 HVPS trip [RF] | 0.23 Refill # 49 03/03 09:32 To 03/03 16:00 6.45 | Int Dump: End of Period | -0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.01 # 50 03/04 08:00 To 03/06 11:22 51.36 | Power bump [OTHER] | 1.00 Injector tuning[OPS],BESCOM timing problem[Diag], r # 55 03/06 12:22 To 03/07 07:44 19.38 | Bunch purity [OPS] | 0.17 Refill # 57 03/07 07:55 To 03/10 01:28 65.56 | S32B:Q5 converter [ES] | 3.55 Replace converter then flush water lines # 63 03/10 05:02 To 03/10 07:59 2.96 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.00 # 64 03/12 08:00 To 03/12 15:54 7.90 | VacValve VM-39-VV02[CTL] | 0.26 Refill # 65 03/12 16:09 To 03/17 01:25 105.26 | S33B:V1 problem [ES] | 2.26 Lost beam again, investigation, refill # 67 03/17 03:40 To 03/18 07:59 28.32 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.01 # 68 03/18 16:00 To 03/20 10:06 42.10 | RF4 Power loss [RF] | 0.29 Refill # 69 03/20 10:23 To 03/21 12:26 26.04 | 2ID PSS trip [ES] | 0.61 Magnet Standardize, refill # 70 03/21 13:02 To 03/22 04:07 15.08 | RF4 cav.Vac.Flt [RF] | 0.18 Refill # 71 03/22 04:18 To 03/24 07:59 51.69 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.00 # 72 03/26 08:00 To 03/26 21:22 13.37 | S15B:MT trip [ES] | 1.19 Convertor swap, refill # 73 03/26 22:33 To 03/29 09:50 59.28 | S39:VV01 Valve trip[CTL] | 0.38 Refill # 74 03/29 10:13 To 04/01 04:25 66.20 | Spurious RadMon.trip[HP] | 0.28 refill # 76 04/01 04:42 To 04/01 07:59 3.30 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 2.39 RF3/RF2 problem[RF],Booster tuning[OAG],refill # 77 04/01 18:23 To 04/02 16:38 22.25 | S40 cav.vac trip [RF] | 0.70 Refill, BPM problem[DIAG] # 78 04/02 17:20 To 04/03 09:04 15.73 | RF4 lost power [RF] | 0.22 Refill # 80 04/03 09:17 To 04/05 16:13 54.93 | 5ID Rad.Mon.failure [HP] | 1.09 Rad. mon. replacement, refill # 81 04/05 17:18 To 04/06 14:02 19.73 | Rad.trip @ refill [OPS] | 0.53 Refill # 83 04/06 14:34 To 04/07 07:59 17.43 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.01 # 86 04/09 08:00 To 04/09 11:33 3.55 | 15ID PSS fault [ES] | 1.12 Investigation[OPS], refill # 87 04/09 12:40 To 04/13 09:30 92.83 | 10ID Rad.Mon. Err. [HP] | 0.29 Investigation, Refill # 88 04/13 09:48 To 04/14 15:59 30.20 | Int Dump: End of Period | 0.00 ------------------------------------------------------------------------------------------------------------------------------------ | | 0.02 # 89 04/15 08:01 To 04/15 15:40 7.65 | iocs31bpm reboot [DIAG] | 0.52 refill # 90 04/15 16:11 To 04/15 18:02 1.85 | 2ID BPLD fault [DIAG | 0.86 Lost again[OPS], refill # 91 04/15 18:53 To 04/16 08:31 13.62 | ACIS relay fault [ES] | 1.20 Investigation, refill # 93 04/16 09:43 To 04/16 17:57 8.24 | 2ID BPLD fault [DIAG] | 0.68 Low inj. efficiency, refill # 94 04/16 18:38 To 04/17 11:58 17.33 | 2ID BPLD fault [DIAG] | 0.47 refill # 96 04/17 12:26 To 04/17 21:23 8.96 | 2ID BPLD fault [DIAG] | 4.14 BPLD repair, validation, refill # 98 04/18 01:32 To 04/20 05:27 51.61 | S36AQ5 failure [ES] | 1.83 Repair, refill * Interuption of delivered beam between 04/18 13:00 To 04/18 13:19 All gaps open to fix rms motion problem [DIAG] #103 04/20 06:58 To 04/20 21:46 14.80 | 2ID BPLD fault [DIAG] | 1.16 Booster RF H2O meter fault, refill #105 04/20 22:56 To 04/20 23:59 1.06 | Int Dump: End of Period | 0.00 Top-Up Mode Statistics ---------------------- Target Current = 102.0, Range +/- 2.0, Minimum Injector Downtime = 8.0 minutes Total Scheduled Topup Time 1239.0 Hours Injector Availability 94.9%