Listing of
Statistics for Run3-2003 (Created Thu Feb 05 22:07:58 CST 2004)
Total Amount
of User Time in this interval 1666.0 Hours
User periods
in this interval
-----------------------------
10/01/2003
08:00 To 10/06/2003 16:00 128.00 Hours, Delivered Beam: 119.43 Hours, 7 Fault(s),
17.06 MTBF, 93.31% of Sched.
Time
10/07/2003
08:00 To 10/13/2003 08:00 144.00 Hours, Delivered Beam: 140.92 Hours, 3 Fault(s),
46.97 MTBF, 97.86% of Sched.
Time
10/15/2003
08:00 To 10/21/2003 08:00 144.00 Hours, Delivered Beam: 142.27 Hours, 2 Fault(s),
71.13 MTBF, 98.80% of Sched.
Time
10/21/2003
16:00 To 10/27/2003 08:00 137.00 Hours, Delivered Beam: 135.12 Hours, 1 Fault(s), 135.12 MTBF, 98.63% of Sched. Time
10/29/2003
08:00 To 11/03/2003 16:00 128.00 Hours, Delivered Beam: 127.57 Hours, 1 Fault(s), 127.57 MTBF, 99.66% of Sched. Time
11/04/2003
08:00 To 11/10/2003 09:00 145.00 Hours, Delivered Beam: 128.11 Hours, 4 Fault(s),
32.03 MTBF, 88.35% of Sched.
Time
11/12/2003
08:00 To 11/18/2003 08:00 144.00 Hours, Delivered Beam: 142.24 Hours, 3 Fault(s),
47.41 MTBF, 98.78% of Sched.
Time
11/18/2003
16:00 To 11/25/2003 08:00 160.00 Hours, Delivered Beam: 155.58 Hours, 2 Fault(s),
77.79 MTBF, 97.24% of Sched.
Time
11/25/2003
16:00 To 11/26/2003 24:00 32.00
Hours, Delivered Beam: 31.99
Hours, 0 Fault(s), 31.99 MTBF,
99.98% of Sched. Time
11/28/2003
08:00 To 12/02/2003 16:00 104.00 Hours, Delivered Beam: 103.56 Hours, 1 Fault(s), 103.56 MTBF, 99.58% of Sched. Time
12/04/2003
08:00 To 12/09/2003 08:00 120.00 Hours, Delivered Beam: 118.04 Hours, 2 Fault(s),
59.02 MTBF, 98.36% of Sched.
Time
12/09/2003
16:00 To 12/15/2003 16:00 144.00 Hours, Delivered Beam: 141.42 Hours, 3 Fault(s),
47.14 MTBF, 98.21% of Sched.
Time
12/16/2003 08:00 To
12/21/2003 24:00 136.00 Hours, Delivered Beam: 135.99 Hours, 0 Fault(s), 135.99 MTBF, 100.00% of Sched.
Time
Delivered
Beam
1622.24 Hours
Percentage of
Scheduled Time 97.38
%
Downtime
During Period
43.69 Hours
Percentage of
scheduled time SR current > 10 ma
98.11 %
Average
Delivered Current During This Period
100.70 mA
Total
integrated Current During This
Period 163.40 A-hr
Mean Fill
Duration in Period 54.09 Hours
Mean Fill
Duration from Poisson Fit
53.26 Hours
Mean Time
Between Faults (MTBF)
55.94 Hours
Faults per
Day of Delivered Beam
0.43
Scheduled
Topup Time
1258.00 Hours
Length Downtime is
associated with the end of a fill.
Valid fills Beginning in this Time
Interval| Reason for |
of The first fill of a
period will have any
Fill#
Start End Duration | Fill Termination |
Downtime downtime before the fill
on the line above.
(min: 1.0)
| |
------------------------------------------------------------------------------------------------------------------------------------
| | 0.07 SR Orbit Correction, 4 minutes [DIAG]
# 1
10/01 08:03 To 10/01 11:40 3.61 | Operator error
.5 [OPS] | 3.18 PS 1.27 DIA.45 OAG.96-Beam loss
# 3
10/01 14:50 To 10/02 17:48 26.96 | S23 RTFB IOC
error [CTL] | 0.52 Beam lost during
recovery process - refill peformed
# 6
10/02 18:19 To 10/02 22:04 3.75 | S9 EPS Trip [SI] | 1.91 Beam restored, S9 EPS Trip again, fill restored
# 8
10/02 23:59 To 10/03 15:21 15.38 | SR-RF3 Off [Unknown] | 0.32 RF restored, beam
restored
# 9
10/03 15:40 To 10/04 04:28 12.79 | S9 EPS Trip [SI] | 1.09 Fault cleared, beam restored
# 11 10/04 05:34
To 10/05 11:40 30.11
| Water pump failure [ME] | 0.88 Switched to back-up pump, beam restored
# 14 10/05 12:33
To 10/05 22:03 9.50
| S9 EPS Trip [SI] | 0.61 Trip reset, beam restored
# 16 10/05 22:39
To 10/06 15:59 17.34
| Int Dump: End of Period | 0.00
------------------------------------------------------------------------------------------------------------------------------------
| |
0.00
# 18 10/07 08:00
To 10/07 11:38 3.64
| S9 EPS Trip [SI] | 2.38 Repaired EPS system, refill, top-up
ongoing
# 19 10/07 14:01
To 10/08 08:34 18.55
| Power bump/ComEd [Other] |
0.45 Bump induced SR-RF4 power change, refill, top-up.
# 20 10/08 09:01
To 10/11 08:36 71.59
| S16:BH1 Glitch [PS] | 0.24 BPLD trip due to beam motion,refill,
resume top-up
# 21 10/11 08:51
To 10/13 08:00 47.14
| Int Dump: End of Period |
-0.00
------------------------------------------------------------------------------------------------------------------------------------
| | 0.00
# 25 10/15 08:00
To 10/16 00:23 16.38
| Vac. Valve Closure [CTL] |
0.51 Valve opened, refill, resume top-up
# 26 10/16 00:53
To 10/18 22:53 69.59
| IOCS25FB .9 [DIAG] | 1.22 refill, beam lost OAG .32 , refill,
resume top-up
* Interruption of delivered beam between
10/16 02:25 To 10/16 02:49 Gaps not returned to user values
# 27 10/18 23:42
To 10/21 07:59 56.29
| Int Dump: End of Period | 0.00
------------------------------------------------------------------------------------------------------------------------------------
| | 0.00
# 29 10/21 16:00
To 10/23 13:48 45.80
| S18/19Raw trip 1.06 [PS] |
1.87 Repair, MPS problem .81 [CTL], refill
# 30 10/23 15:40
To 10/27 07:59 89.32
| Int Dump: End of Period | 0.00
------------------------------------------------------------------------------------------------------------------------------------
| | 0.00
# 31 10/29 08:00
To 10/31 04:25 44.41
| SR valve closure [CTL] | 0.43 VM-04-VV01 re-opened, ring filled,
resumed top-up
# 32 10/31 04:50
To 11/03 15:59 83.15
| Int Dump: End of Period | 0.00
------------------------------------------------------------------------------------------------------------------------------------
| | 0.00
# 33 11/04 08:00
To 11/04 16:23 8.40
| PEM Steering Error [OAG] |
0.29 Refill, resume top-up
# 34 11/04 16:41
To 11/08 23:55 103.23
| SR-RF4 Trip [RF] | 0.33 Power monitor trip, reset, refill,
resume top-up
# 35 11/09 00:15
To 11/09 01:34 1.32
| UPS Fault [IT] | 9.73 recovery of systems, refill, resume
top-up
# 36 11/09 11:18
To 11/10 00:09 12.85
| UPS Fault [IT] | 6.53 UPS by-passed, recovery, refill, resume
top-up
# 37 11/10 06:41
To 11/10 08:59 2.31
| Int Dump: End of Period | 0.00
------------------------------------------------------------------------------------------------------------------------------------
| | 0.01
# 39 11/12 08:00
To 11/12 23:15 15.24
| IOCS25FB Hung Task [DIA] |
0.40 Beam lost during reboot, refilled SR
# 41 11/12 23:38
To 11/13 22:17 22.64
| SR Gate Valve [CTL] | 0.40 SR Gate Valve VM:02:VV02 closed, refill
# 44 11/13 22:40
To 11/17 13:09 86.48
| 22ID EPS trip [SI] | 0.96 Recover from EPS trip, refill
# 52 11/17 14:07
To 11/18 07:59 17.88
| Int Dump: End of Period | 0.00
------------------------------------------------------------------------------------------------------------------------------------
| | 0.00
# 54 11/18 16:00
To 11/24 06:57 134.95
| UPS AC breaker trip [IT] |
3.74 Recover,RTFB problem 0.3h [Diag],refill
# 55 11/24 10:41
To 11/24 14:37 3.93
| S32/33 Raw PS Trip [ES] | 0.68 Reset, conditioning, refill
# 56 11/24 15:18
To 11/25 07:59 16.69
| Int Dump: End of Period | 0.00
------------------------------------------------------------------------------------------------------------------------------------
| |
0.01
# 57 11/25 16:00
To 11/26 23:59 31.99
| Int Dump: End of Period | 0.00
------------------------------------------------------------------------------------------------------------------------------------
| |
0.00
# 58 11/28 08:00
To 11/29 04:04 20.07
| SR-RF4 pwr mon trip [RF] |
0.43 Reset RF system, refill, resume top-up
# 59 11/29 04:30
To 12/02 15:59 83.49
| Int Dump: End of Period | 0.00
------------------------------------------------------------------------------------------------------------------------------------
| | 0.00
# 64 12/04 08:00
To 12/05 12:21 28.35
| BPLD Trip [Unknown] | 0.46 Still under investigation, refill,
resume top-up
# 65 12/05 12:48
To 12/09 06:30 89.69
| S22 supplies trip [PS] | 1.50 Recover, refill, user period ends
------------------------------------------------------------------------------------------------------------------------------------
| | 0.01
# 67 12/09 16:00
To 12/09 22:34 6.57
| Rad.Mon. fault [UES] | 0.59 Investigation, refill, resume top-up
# 68 12/09 23:09
To 12/11 21:34 46.41
| 34ID PSS trip [SI] | 0.70 Reset, investigate, refill
# 69 12/11 22:16
To 12/13 05:19 31.06
| S17BQ4 PS fault [PS] | 1.29 Supply swap, refill
# 70 12/13 06:36
To 12/15 15:59 57.38
| Int Dump: End of Period | 0.00
------------------------------------------------------------------------------------------------------------------------------------
| | 0.00
# 72 12/16 08:00
To 12/21 23:59 135.99
| Int Dump: End of Period | 0.00
Top-Up Mode
Statistics
----------------------
Target
Current Range +/- 2.0, Minimum Injector Downtime = 8.0 minutes
Total
Current in Range during Scheduled Topup
Time 95.16 %
Current in Range during Delivered Beam
Time 97.72 %
Injector Availability 97.59 %