Summary of FY2011 Operational Statistics | ||||||||||||
Run Identifier | Scheduled User Hours | Storage Ring Availability [hours] | Storage Ring Availability [%] | X-ray Availability [hours] | X-ray Availability [%] | Injector Availibility | Faults | Mean Time to Recovery [hours] | Average Fill Duration without aFault [hours] | Faults Per Day of Delivered Beam | Delivered Integrated Current [A-hr] | Average Current [ma] |
Run 10-3 | 1553.0 | 1521.2 | 97.9% | 1521.2 | 97.9% | 97.6% | 19 | 1.68 | 80.1 | 0.30 | 154.5 | 101.5 |
Run 11-1 | 1719.0 | 1689.8 | 98.3% | 1689.8 | 98.3% | 97.3% | 14 | 2.08 | 120.7 | 0.20 | 169.4 | 100.2 |
Run 11-2 | 1727.9 | 1695.1 | 98.1% | 1695.1 | 98.1% | 98.5% | 23 | 1.43 | 73.7 | 0.33 | 169.1 | 99.7 |
Fiscal Year | 5000.0 | 4906.1 | 98.1% | 4906.1 | 98.1% | 97.6% | 56 | 1.68 | 87.6 | 0.27 | 492.9 | 100.5 |
Updated | 8/25/2011 | Data through end of Run 2011-2 |