| Summary of FY2012 Operational Statistics | ||||||||||||
| Run Identifier | Scheduled User Hours | Storage Ring Availability [hours] | Storage Ring Availability [%] | X-ray Availability [hours] | X-ray Availability [%] | Injector Availibility | Faults | Mean Time to Recovery [hours] | Average Fill Duration without aFault [hours] | Faults Per Day of Delivered Beam | Delivered Integrated Current [A-hr] | Average Current [ma] |
| Run 11-3 | 1545.0 | 1538.1 | 99.6% | 1538.1 | 99.6% | 98.4% | 7 | 0.99 | 219.7 | 0.11 | 154.3 | 100.3 |
| Run 12-1 | 1727.0 | 1722.4 | 99.7% | 1722.4 | 99.7% | 97.8% | 6 | 0.77 | 287.1 | 0.08 | 171.7 | 99.7 |
| Run 12-2 | 1728.0 | 1708.9 | 98.9% | 1708.9 | 98.9% | 99.0% | 12 | 1.59 | 142.4 | 0.17 | 171.3 | 100.2 |
| Fiscal Year | 5000.0 | 4969.4 | 99.4% | 4969.4 | 99.4% | 98.4% | 25 | 1.22 | 198.8 | 0.12 | 497.3 | 100.1 |
| Updated | 8/24/2012 | Data through end of Run 2012-2 | ||||||||||