Summary of FY2013 Operational Statistics | ||||||||||||
Run Identifier | Scheduled User Hours | Storage Ring Availability [hours] | Storage Ring Availability [%] | X-ray Availability [hours] | X-ray Availability [%] | Injector Availibility | Faults | Mean Time to Recovery [hours] | Average Fill Duration without aFault [hours] | Faults Per Day of Delivered Beam | Delivered Integrated Current [A-hr] | Average Current [ma] |
Run 12-3 | 1569.0 | 1535.1 | 97.8% | 1535.1 | 97.8% | 98.1% | 19 | 1.78 | 80.8 | 0.30 | 153.5 | 100.0 |
Run 13-1 | 1727.0 | 1707.6 | 98.9% | 1707.6 | 98.9% | 99.1% | 10 | 1.94 | 170.8 | 0.14 | 171.2 | 100.2 |
Run 13-2 | 1704.0 | 1652.2 | 97.0% | 1652.2 | 97.0% | 92.9% | 20 | 2.59 | 82.6 | 0.29 | 162.8 | 98.5 |
Fiscal Year | 5000.0 | 4895.0 | 97.9% | 4895.0 | 97.9% | 98.1% | 49 | 2.14 | 99.9 | 0.24 | 487.4 | 99.6 |
Updated | 8/23/2013 | Data through end of Run 2013-2 |