Summary of FY2014 Operational Statistics | ||||||||||||
Run Identifier | Scheduled User Hours | Storage Ring Availability [hours] | Storage Ring Availability [%] | X-ray Availability [hours] | X-ray Availability [%] | Injector Availibility | Faults | Mean Time to Recovery [hours] | Average Fill Duration without aFault [hours] | Faults Per Day of Delivered Beam | Delivered Integrated Current [A-hr] | Average Current [ma] |
Run 13-3 | 1545.0 | 1511.5 | 97.8% | 1511.5 | 97.8% | 97.8% | 15 | 2.23 | 100.8 | 0.24 | 151.7 | 100.3 |
Run 14-1 | 1679.0 | 1656.7 | 98.7% | 1656.7 | 98.7% | 98.4% | 11 | 2.03 | 150.6 | 0.16 | 164.3 | 99.2 |
Run 14-2 | 1776.0 | 1732.6 | 97.6% | 1732.6 | 97.6% | 98.0% | 25 | 1.73 | 69.3 | 0.35 | ||
Fiscal Year | 5000.0 | 4900.8 | 98.0% | 4900.8 | 98.0% | 97.8% | 51 | 1.94 | 96.1 | 0.25 | 316.0 | 64.5 |
Updated | 8/26/2014 | Data through end of Run 2014-2 |