Summary of FY2017 Operational Statistics | ||||||||||||
Run Identifier | Scheduled User Hours | Storage Ring Availability [hours] | Storage Ring Availability [%] | X-ray Availability [hours] | X-ray Availability [%] | Injector Availibility | Faults | Mean Time to Recovery [hours] | Average Fill Duration without aFault [hours] | Faults Per Day of Delivered Beam | Delivered Integrated Current [A-hr] | Average Current [ma] |
Run 16-3 | 1561.0 | 1539.3 | 98.6% | 1539.3 | 98.6% | 98.2% | 14 | 1.55 | 110.0 | 0.22 | 154.6 | 100.5 |
Run 17-1 | 1719.0 | 1698.0 | 98.8% | 1698.0 | 98.8% | 98.8% | 12 | 1.75 | 141.5 | 0.17 | 170.6 | 100.5 |
Run 17-2 | 1720.0 | 1610.9 | 93.7% | 1610.9 | 93.7% | 99.3% | 10 | 10.91 | 161.1 | 0.15 | 162.8 | 101.0 |
Fiscal Year | 5000.0 | 4848.3 | 97.0% | 4848.3 | 97.0% | 98.2% | 36 | 4.21 | 134.7 | 0.18 | 488.0 | 100.7 |
Updated | 9/3/2017 | Data through end of Run 2017-2 |