Summary of FY2018 Operational Statistics | ||||||||||||
Run Identifier | Scheduled User Hours | Storage Ring Availability [hours] | Storage Ring Availability [%] | X-ray Availability [hours] | X-ray Availability [%] | Injector Availibility | Faults | Mean Time to Recovery [hours] | Average Fill Duration without aFault [hours] | Faults Per Day of Delivered Beam | Delivered Integrated Current [A-hr] | Average Current [ma] |
Run 17-3 | 1553.0 | 1532.0 | 98.6% | 1532.0 | 98.6% | 98.7% | 14 | 1.50 | 109.4 | 0.22 | 153.7 | 100.3 |
Run 18-1 | 1743.0 | 1710.1 | 98.1% | 1710.1 | 98.1% | 97.8% | 23 | 1.43 | 74.4 | 0.32 | 153.7 | 89.9 |
Run 18-2 | 1704.0 | 1616.7 | 94.9% | 1616.7 | 94.9% | 97.4% | 15 | 5.82 | 107.8 | 0.22 | 162.3 | 100.4 |
Fiscal Year | 5000.0 | 4858.8 | 97.2% | 4858.8 | 97.2% | 98.7% | 52 | 2.72 | 93.4 | 0.26 | 469.7 | 96.7 |
Updated | 9/11/2018 | Data through end of Run 2018-2 |