FY 2019 Reliability Summary |
|
|
|
|
|
|
|
|
|
|
|
Reliability
Budget |
|
|
|
|
|
|
System |
Unavailability
Allotment |
|
Number of Faults |
Mean Time to Beam
Loss |
Faults Per |
|
|
Day |
RF |
0.5% |
|
|
200 |
0.12 |
|
|
Diagnostics |
0.1% |
|
|
800 |
0.03 |
|
|
PS |
0.5% |
|
|
200 |
0.12 |
|
|
Controls |
0.3% |
|
|
500 |
0.05 |
|
|
Network |
0.1% |
|
|
4800 |
0.01 |
|
|
Interlocks |
0.2% |
|
|
800 |
0.03 |
|
|
Accelerator |
0.1% |
|
|
2400 |
0.01 |
|
|
Beamline |
0.1% |
|
|
2400 |
0.01 |
|
|
Radiation |
0.1% |
|
|
1600 |
0.02 |
|
|
MOM |
0.4% |
|
|
480 |
0.05 |
|
|
S&A |
0.0% |
|
|
48000 |
0.00 |
|
|
Operations & Analysis |
0.1% |
|
|
4800 |
0.01 |
|
|
Physics |
0.0% |
|
|
48000 |
0.00 |
|
|
ID-FE |
0.1% |
|
|
4800 |
0.01 |
|
|
ID-FE/MD |
not specified |
|
|
|
|
|
|
ID-FE/XFE |
not specified |
|
|
|
|
|
|
Utilities |
0.3% |
|
|
800 |
0.03 |
|
|
Electrical - APS |
0.1% |
|
|
2400 |
0.01 |
|
|
Electrical - ANL |
0.2% |
|
|
2400 |
0.01 |
|
|
Cooling - ANL |
0.1% |
|
|
2400 |
0.01 |
|
|
Other |
0.2% |
|
|
1200 |
0.02 |
|
|
Unidentified |
0.1% |
|
|
1200 |
0.02 |
|
|
Total |
2.9% |
|
|
49.6 |
0.48 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Data through Run 2019-2 |
|
|
|
|
|
|
|
|
|
|
|
|
FY 2018 Actual |
Unavailability |
Unavailability |
Number |
Mean Time |
Faults Per |
|
|
Percent |
Hours |
of Faults |
to Beam Loss |
Day |
RF |
0.75% |
37.72 |
19 |
258.4 |
0.09 |
User Downtime Hours |
90.82 |
Diagnostics |
0.00% |
0.00 |
0 |
|
0.00 |
|
|
PS |
0.40% |
20.05 |
11 |
446.3 |
0.05 |
Scheduled Hours |
5000 |
Controls |
0.19% |
9.70 |
4 |
1227.3 |
0.02 |
|
|
Network |
0.00% |
0.00 |
0 |
|
0.00 |
Delivered Hours |
4909.2 |
Safety Interlocks |
0.03% |
1.48 |
2 |
2454.6 |
0.01 |
|
|
Radiation Monitors |
0.04% |
1.77 |
2 |
2454.6 |
0.01 |
User Availability |
98.18% |
Water/ME |
0.23% |
11.50 |
6 |
818.2 |
0.03 |
|
|
Vacuum |
0.01% |
0.40 |
1 |
4909.2 |
0.00 |
Longest period w/out a fault |
377.46 |
Operations |
0.01% |
0.58 |
2 |
2454.6 |
0.01 |
|
|
ID-FE |
0.00% |
0.00 |
0 |
|
0.00 |
|
|
Utilities |
0.06% |
2.95 |
2 |
2454.6 |
0.01 |
|
|
Electrical - APS |
0.00% |
0.00 |
0 |
|
0.00 |
|
|
Electrical - ANL |
0.06% |
2.95 |
2 |
2454.6 |
0.01 |
|
|
Cooling - ANL |
0.00% |
0.00 |
0 |
|
0.00 |
|
|
Other |
0.01% |
0.37 |
1 |
4909.2 |
0.00 |
|
|
Unidentified |
0.09% |
4.30 |
8 |
613.6 |
0.04 |
|
|
APS-U |
|
|
|
|
0.00 |
|
|
Total |
1.82% |
90.82 |
58 |
84.6 |
0.28 |
|
|
|
|
|
|
|
|
|
|
Run 2018-3 |
Unavailability |
Unavailability |
Number |
Mean Time |
Faults Per |
|
|
Percent |
Hours |
of Faults |
to Beam Loss |
Day |
|
|
|
|
|
|
|
|
RF |
1.27% |
19.85 |
6 |
254.4 |
0.09 |
User Downtime Hours |
34.63 |
Diagnostics |
0.00% |
|
|
|
0.00 |
|
|
PS |
0.55% |
8.57 |
3 |
508.8 |
0.05 |
Scheduled Hours |
1561.0 |
Controls |
0.00% |
|
|
|
0.00 |
Delivered Hours |
1526.4 |
Network |
|
|
|
|
|
|
|
Safety Interlocks |
0.05% |
0.72 |
1 |
1526.4 |
0.02 |
User Availability |
97.78% |
Radiation Monitors |
0.00% |
|
|
|
0.00 |
|
|
Water/ME |
0.21% |
3.27 |
1 |
1526.4 |
0.02 |
|
|
Vacuum |
0.00% |
|
|
|
0.00 |
Longest period w/out a fault |
281.71 |
Operations |
0.04% |
0.58 |
2 |
763.2 |
0.03 |
|
|
ID-FE |
0.00% |
|
|
|
0.00 |
|
|
ID-FE/MD |
0.00% |
|
|
|
0.00 |
|
|
ID-FE/XFE |
0.00% |
|
|
|
0.00 |
|
|
Utilities |
0.04% |
0.55 |
1 |
1526.4 |
0.02 |
|
|
Electrical - APS |
0.00% |
|
|
|
0.00 |
|
|
Electrical - ANL |
0.04% |
0.55 |
1 |
1526.4 |
0.02 |
|
|
Cooling - ANL |
0.00% |
|
|
|
0.00 |
|
|
Other |
0.00% |
|
|
|
0.00 |
|
|
Unidentified |
0.07% |
1.10 |
2 |
763.2 |
|
|
|
|
|
|
|
|
|
|
|
Total |
2.27% |
34.63 |
16 |
95.4 |
0.25 |
|
|
|
|
|
|
|
|
|
|
Run 2019-1 |
Unavailability |
Unavailability |
Number |
Mean Time |
Faults Per |
|
|
Percent |
Hours |
of Faults |
to Beam Loss |
Day |
|
|
|
|
|
|
|
|
RF |
0.70% |
11.98 |
6 |
281.8 |
0.09 |
User Downtime Hours |
28.03 |
Diagnostics |
0.00% |
|
|
|
0.00 |
|
|
PS |
0.51% |
8.80 |
6 |
281.8 |
0.09 |
Scheduled Hours |
1719 |
Controls |
0.00% |
|
|
|
0.00 |
Delivered Hours |
1691.0 |
Network |
0.00% |
|
|
|
|
|
|
Safety Interlocks |
0.04% |
0.77 |
1 |
1691.0 |
0.01 |
User Availability |
98.4% |
Radiation Monitors |
0.10% |
1.77 |
2 |
845.5 |
0.03 |
|
|
MOM |
0.17% |
2.90 |
1 |
1691.0 |
0.01 |
|
|
Vacuum |
0.02% |
0.40 |
1 |
1691.0 |
0.01 |
Longest period w/out a fault |
377.46 |
Operations |
0.00% |
|
|
|
0.00 |
|
|
ID-FE |
0.00% |
|
|
|
0.00 |
|
|
Utilities |
0.00% |
|
|
|
0.00 |
|
|
Electrical - APS |
0.00% |
|
|
|
0.00 |
|
|
Electrical - ANL |
0.00% |
|
|
|
0.00 |
|
|
Cooling - ANL |
0.00% |
|
|
|
0.00 |
|
|
Other |
0.00% |
|
|
|
0.00 |
|
|
Unidentified |
0.08% |
1.42 |
2 |
845.5 |
0.03 |
|
|
Total |
1.66% |
28.03 |
19 |
89.0 |
0.27 |
|
|
|
|
|
|
|
|
|
|
Run 2019-2 |
Unavailability |
Unavailability |
Number |
Mean Time |
Faults Per |
|
|
Percent |
Hours |
of Faults |
to Beam Loss |
Day |
|
|
|
|
|
|
|
|
RF |
0.34% |
5.88 |
7 |
218.1 |
0.11 |
User Downtime Hours |
28.15 |
Diagnostics |
0.00% |
0.00 |
0 |
|
0.00 |
|
|
PS |
0.16% |
2.68 |
2 |
763.2 |
0.03 |
Scheduled Hours |
1720.0 |
Controls |
0.56% |
9.70 |
4 |
381.6 |
0.06 |
Delivered Hours |
1691.8 |
Network |
0.00% |
|
|
|
|
|
|
Safety Interlocks |
0.00% |
|
|
|
0.00 |
User Availability |
98.4% |
Radiation Monitors |
0.00% |
|
|
|
0.00 |
|
|
MOM |
0.31% |
5.33 |
4 |
381.6 |
0.06 |
|
|
Vacuum |
0.00% |
|
|
|
0.00 |
Longest period w/out a fault |
326.44 |
Operations & Analysis |
0.00% |
|
|
|
0.00 |
|
|
Physics |
0.00% |
|
|
|
0.00 |
|
|
ID-FE |
0.00% |
|
|
|
0.00 |
|
|
ID-FE/MD |
0.00% |
|
|
|
0.00 |
|
|
UES |
0.00% |
|
|
|
0.00 |
|
|
Utilities |
0.14% |
2.40 |
1 |
1526.4 |
0.02 |
|
|
Electrical - APS |
0.00% |
|
|
|
0.00 |
|
|
Electrical - ANL |
0.14% |
2.40 |
1 |
1526.4 |
0.02 |
|
|
Cooling - ANL |
0.00% |
|
|
|
0.00 |
|
|
Other |
0.02% |
0.37 |
1 |
1526.4 |
0.02 |
|
|
Unidentified |
0.10% |
1.78 |
4 |
381.6 |
0.06 |
|
|
APS-U |
0.00% |
|
|
|
0.00 |
|
|
Total |
1.64% |
28.15 |
23 |
73.6 |
0.33 |
|
|
|
|
|
|
|
|
Updated |
8/21/2019 |
|
|
|
|
|
|
|
|