Summary of FY2019 Operational Statistics | ||||||||||||
Run Identifier | Scheduled User Hours | Storage Ring Availability [hours] | Storage Ring Availability [%] | X-ray Availability [hours] | X-ray Availability [%] | Injector Availibility | Faults | Mean Time to Recovery [hours] | Average Fill Duration without aFault [hours] | Faults Per Day of Delivered Beam | Delivered Integrated Current [A-hr] | Average Current [ma] |
Run 18-3 | 1561.0 | 1526.4 | 97.8% | 1526.4 | 97.8% | 97.3% | 16 | 2.16 | 95.4 | 0.25 | 151.6 | 99.3 |
Run 19-1 | 1719.0 | 1691.0 | 98.4% | 1691.0 | 98.4% | 98.1% | 19 | 1.48 | 89.0 | 0.27 | 169.5 | 100.2 |
Run 19-2 | 1720.0 | 1691.8 | 98.4% | 1691.8 | 98.4% | 98.8% | 23 | 1.22 | 73.6 | 0.33 | 168.0 | 99.3 |
Fiscal Year | 5000.0 | 4909.2 | 98.2% | 4909.2 | 98.2% | 97.3% | 58 | 1.57 | 84.6 | 0.28 | 489.0 | 99.6 |
Updated | 8/21/2019 | Data through end of Run 2019-2 |