FY 2020 Reliability Summary |
|
|
|
|
|
|
|
|
|
|
|
Reliability
Budget |
|
|
|
|
|
|
System |
Unavailability
Allotment |
|
Number of Faults |
Mean Time to Beam
Loss |
Faults Per |
|
|
Day |
RF |
0.5% |
|
|
200 |
0.12 |
|
|
Diagnostics |
0.1% |
|
|
800 |
0.03 |
|
|
PS |
0.5% |
|
|
200 |
0.12 |
|
|
Controls |
0.3% |
|
|
500 |
0.05 |
|
|
Network |
0.1% |
|
|
4800 |
0.01 |
|
|
Interlocks |
0.2% |
|
|
800 |
0.03 |
|
|
Accelerator |
0.1% |
|
|
2400 |
0.01 |
|
|
Beamline |
0.1% |
|
|
2400 |
0.01 |
|
|
Radiation |
0.1% |
|
|
1600 |
0.02 |
|
|
MOM |
0.4% |
|
|
480 |
0.05 |
|
|
S&A |
0.0% |
|
|
48000 |
0.00 |
|
|
Operations & Analysis |
0.1% |
|
|
4800 |
0.01 |
|
|
Physics |
0.0% |
|
|
48000 |
0.00 |
|
|
ID-FE |
0.1% |
|
|
4800 |
0.01 |
|
|
ID-FE/MD |
not specified |
|
|
|
|
|
|
ID-FE/XFE |
not specified |
|
|
|
|
|
|
Utilities |
0.3% |
|
|
800 |
0.03 |
|
|
Electrical - APS |
0.1% |
|
|
2400 |
0.01 |
|
|
Electrical - ANL |
0.2% |
|
|
2400 |
0.01 |
|
|
Cooling - ANL |
0.1% |
|
|
2400 |
0.01 |
|
|
Other |
0.2% |
|
|
1200 |
0.02 |
|
|
Unidentified |
0.1% |
|
|
1200 |
0.02 |
|
|
Total |
2.9% |
|
|
49.6 |
0.48 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Data through Run 2020-2 |
|
|
|
|
|
|
|
|
|
|
|
|
FY 2020 Actual |
Unavailability |
Unavailability |
Number |
Mean Time |
Faults Per |
|
|
Percent |
Hours |
of Faults |
to Beam Loss |
Day |
RF |
0.23% |
11.50 |
10 |
485.3 |
0.05 |
User Downtime Hours |
146.42 |
Diagnostics |
0.00% |
0.00 |
0 |
|
0.00 |
|
|
PS |
0.23% |
11.70 |
9 |
539.2 |
0.04 |
Scheduled Hours |
5000 |
Controls |
0.16% |
7.85 |
3 |
1617.7 |
0.01 |
|
|
Network |
0.00% |
0.00 |
0 |
|
0.00 |
Delivered Hours |
4853.2 |
Safety Interlocks |
0.00% |
0.00 |
0 |
|
0.00 |
|
|
Radiation Monitors |
0.04% |
1.97 |
2 |
2426.6 |
0.01 |
User Availability |
97.06% |
Water/ME |
1.60% |
79.90 |
3 |
1617.7 |
0.01 |
|
|
Vacuum |
0.00% |
0.00 |
0 |
|
0.00 |
Longest period w/out a fault |
493.51 |
Operations |
0.12% |
6.18 |
3 |
1617.7 |
0.01 |
|
|
AOP |
0.03% |
1.57 |
0 |
|
0.00 |
|
|
Utilities |
0.35% |
17.65 |
3 |
1617.7 |
0.01 |
|
|
Electrical - APS |
0.00% |
0.00 |
0 |
|
0.00 |
|
|
Electrical - ANL |
0.30% |
15.17 |
2 |
2426.6 |
0.01 |
|
|
Cooling - ANL |
0.05% |
2.48 |
1 |
4853.2 |
0.00 |
|
|
Other |
0.11% |
5.33 |
2 |
2426.6 |
0.01 |
|
|
Unidentified |
0.01% |
0.60 |
1 |
4853.2 |
0.00 |
|
|
APS-U |
|
|
|
|
0.00 |
|
|
Total |
2.89% |
144.25 |
36 |
134.8 |
0.18 |
|
|
|
|
|
|
|
|
|
|
Run 2019-3 |
Unavailability |
Unavailability |
Number |
Mean Time |
Faults Per |
|
|
Percent |
Hours |
of Faults |
to Beam Loss |
Day |
|
|
|
|
|
|
|
|
RF |
0.22% |
3.52 |
3 |
505.4 |
0.05 |
User Downtime Hours |
84.78 |
Diagnostics |
0.00% |
|
|
|
0.00 |
|
|
PS |
0.12% |
1.92 |
2 |
758.1 |
0.03 |
Scheduled Hours |
1601.0 |
Controls |
0.19% |
3.02 |
0 |
|
0.00 |
Delivered Hours |
1516.2 |
Network |
|
|
|
|
|
|
|
Safety Interlocks |
0.00% |
|
|
|
0.00 |
User Availability |
94.70% |
Radiation Monitors |
0.08% |
1.28 |
1 |
1516.2 |
0.02 |
|
|
Water/ME |
4.56% |
72.98 |
1 |
1516.2 |
0.02 |
|
|
Vacuum |
0.00% |
|
|
|
0.00 |
Longest period w/out a fault |
493.51 |
Operations |
0.13% |
2.07 |
1 |
1516.2 |
0.02 |
|
|
ID-FE |
0.00% |
|
|
|
0.00 |
|
|
ID-FE/MD |
0.00% |
|
|
|
0.00 |
|
|
ID-FE/XFE |
0.00% |
|
|
|
0.00 |
|
|
Utilities |
0.00% |
|
|
|
0.00 |
|
|
Electrical - APS |
0.00% |
|
|
|
0.00 |
|
|
Electrical - ANL |
0.00% |
|
|
|
0.00 |
|
|
Cooling - ANL |
0.00% |
|
|
|
0.00 |
|
|
Other |
0.00% |
|
|
|
0.00 |
|
|
Unidentified |
0.00% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Total |
5.30% |
84.78 |
8 |
189.5 |
0.13 |
|
|
|
|
|
|
|
|
|
|
Run 2020-1 |
Unavailability |
Unavailability |
Number |
Mean Time |
Faults Per |
|
|
Percent |
Hours |
of Faults |
to Beam Loss |
Day |
|
|
|
|
|
|
|
|
RF |
0.22% |
4.42 |
5 |
386.7 |
0.06 |
User Downtime Hours |
34.40 |
Diagnostics |
0.00% |
|
|
|
0.00 |
|
|
PS |
0.14% |
2.77 |
2 |
966.8 |
0.02 |
Scheduled Hours |
1968 |
Controls |
0.15% |
3.00 |
2 |
966.8 |
0.02 |
Delivered Hours |
1933.6 |
Network |
0.00% |
|
|
|
|
|
|
Safety Interlocks |
0.00% |
|
|
|
0.00 |
User Availability |
98.3% |
Radiation Monitors |
0.03% |
0.68 |
1 |
1933.6 |
0.01 |
|
|
MOM |
0.25% |
4.88 |
0 |
|
0.00 |
|
|
Vacuum |
0.00% |
|
|
|
0.00 |
Longest period w/out a fault |
430.8 |
Operations |
0.15% |
2.88 |
1 |
1933.6 |
0.01 |
|
|
AOP |
0.08% |
1.57 |
0 |
|
0.00 |
|
|
Utilities |
0.56% |
11.08 |
2 |
966.8 |
0.02 |
|
|
Electrical - APS |
0.00% |
|
|
|
0.00 |
|
|
Electrical - ANL |
0.44% |
8.60 |
1 |
1933.6 |
0.01 |
|
|
Cooling - ANL |
0.13% |
2.48 |
1 |
1933.6 |
0.01 |
|
|
Other |
0.16% |
3.13 |
2 |
966.8 |
0.02 |
|
|
Unidentified |
0.00% |
|
|
|
0.00 |
|
|
Total |
1.78% |
34.42 |
15 |
128.9 |
0.19 |
|
|
|
|
|
|
|
|
|
|
Run 2020-2 |
Unavailability |
Unavailability |
Number |
Mean Time |
Faults Per |
|
|
Percent |
Hours |
of Faults |
to Beam Loss |
Day |
|
|
|
|
|
|
|
|
RF |
0.25% |
3.57 |
2 |
758.1 |
0.03 |
User Downtime Hours |
27.23 |
Diagnostics |
0.00% |
|
|
|
0.00 |
|
|
PS |
0.49% |
7.02 |
5 |
303.2 |
0.08 |
Scheduled Hours |
1431.0 |
Controls |
0.13% |
1.83 |
1 |
1516.2 |
0.02 |
Delivered Hours |
1403.4 |
Network |
0.00% |
|
|
|
|
|
|
Safety Interlocks |
0.00% |
|
|
|
0.00 |
User Availability |
98.1% |
Radiation Monitors |
0.00% |
|
|
|
0.00 |
|
|
MOM |
0.14% |
2.03 |
2 |
758.1 |
0.03 |
|
|
Vacuum |
0.00% |
|
|
|
0.00 |
Longest period w/out a fault |
430.8 |
AOP |
0.09% |
1.23 |
1 |
1516.2 |
0.02 |
|
|
MCR |
0.15% |
2.18 |
0 |
|
0.00 |
|
|
ID-FE |
0.00% |
|
|
|
0.00 |
|
|
ID-FE/MD |
0.00% |
|
|
|
0.00 |
|
|
UES |
0.00% |
|
|
|
0.00 |
|
|
Utilities |
0.46% |
6.57 |
1 |
1516.2 |
0.02 |
|
|
Electrical - APS |
0.00% |
|
|
|
0.00 |
|
|
Electrical - ANL |
0.46% |
6.57 |
1 |
1516.2 |
0.02 |
|
|
Cooling - ANL |
0.00% |
|
|
|
0.00 |
|
|
Other |
0.15% |
2.20 |
|
|
0.00 |
|
|
Unidentified |
0.04% |
0.60 |
1 |
1516.2 |
0.02 |
|
|
APS-U |
0.00% |
|
|
|
0.00 |
|
|
Total |
1.90% |
27.23 |
13 |
108.0 |
0.22 |
|
|
|
|
|
|
|
|
Updated |
9/29/2020 |
|
|
|
|
|
|
|
|