1.1 Bug Fixes for Elements
- Pelegant no longer hangs on CENTER elements with T=1.
- There was a bug in division of CSBEND elements when tracking-based matrices and edge effects
were used, as reported by V. Sajaev (APS).
- Fixed issues with computation of radiation integrals on large closed orbits for CCBEND and