10.19 CPICKUP—Optical stochastic cooling pickup element—records particle position

Optical stochastic cooling pickup element—records particle position
Parallel capable? : yes
GPU capable? : no
Back-tracking capable? : no






Parameter Name UnitsType Default

Description






ID STRINGNULL

System identifier






UPDATE_INTERVAL long 0

Interval in turns for sampling data and updating filter output.






START_PASS long -1

If positive, first pass on which to perform computations.






END_PASS long -1

If positive, last pass on which to perform computations.






DX M double 0.0

Horizontal offset (subtracted from pickup signal).






DY M double 0.0

Vertical offset (subtracted from pickup signal)






BUNCHED_BEAM_MODE short 1

If non-zero, run in bunched beam mode.






GROUP string NULL

Optionally used to assign an element to a group, with a user-defined name. Group names will appear in the parameter output file in the column ElementGroup